DESIGNED FOR COMFORT, BUILT TO LAST
MAC container homes come in two specifications: standard and superior. The standard specification is used for temporary office or living accommodation for use on building sites, farms, industrial parks and people working from home.
To qualify as a permanent residence and meet the terms of buildings and contents insurance, we build superior homes to the latest building regulations to provide additional features such as improved insulation, security and resistance to risks such as fire or flooding. All our units are 30 minute Fire Rated.
Standard specification (20 x 8 single bed unit) | Building regulations specification | |
---|---|---|
Price | £17,050 (incl. VAT) | £28,850 (incl. VAT) |
Flat sided or corrugated panels | Yes | L1A: roof 0.17, wall 0.20, floor 0.18 |
External colour | Client specified | Client specified |
Lifting points | 4 x high level | 4 x high level |
Forklift pockets | Optional | Optional |
Jacklegs | Optional | Optional |
Staircase brackets | Optional | Optional |
Increased steel work to enable stacking | Optional | Yes |
Underdrawn and insulated floor | 30mm cladding | 100mm Recticel, Part L1A |
Heating and hot water | Dimplex heating and instantaneous hot water | Part L1A |
Ventilation | Standard anti-condensational ventilation | Part L1A |
Lighting | Standard flourescant | Part L1A |
External door | Kirncroft with multi-locking system and closer | Kirncroft with multi-locking system and closer |
Windows | Upvc double glazed with Kirncroft shutters 914mm x 914mm 600mkm x 600mm at high-level with obscured glass and mesh guards |
Upvc double glazed with Kirncroft shutters 914mm x 914mm 600mkm x 600mm at high-level with obscured glass and mesh guards |
Wall insulation | 80mm cladding | 35mm cladding and 50mm Recticel |
Ceiling insulation | 30mm spray foam | 50mm spray foam |
Wall and ceiling lining | Plasterboard painted with emulsion | Plasterboard painted with emulsion |
Internal partition insulation | 80mm cladding | 35mm cladding plus acoustic cladding to 35Db |
Flooring | 15mm ply with 2mm vinyl | 18mm ply with 2mm vinyl Increased specification to meet local fire regulations where required |